PD3U Spectrum Analyzer Partial Discharge Detector and RIV Meter
The PD3U Spectrum Analyzer Partial Discharge Detector and RIV Meter complies with the following standards: - IEC 60270-2000 - IEEE C57.12.90 - NEMA 107-1987 - CISPR 18-2 - ANSI C63.3-1996 - VDE 876 - DIN EN 55016-1-1 These standards pertain to partial discharge measurements, radio influence voltage testing, and electromagnetic compatibility.

PD2U Partial Discharge Detector
The PD2U Partial Discharge Detector complies with IEC 60270, as stated on the product page.

AQUILA Partial Discharge Acquisition Unit
The AQUILA Partial Discharge Acquisition Unit complies with IEC 60270, IEC 61326-1, and IEC 61010-1 standards.

AQUILA Partial Discharge Acquisition Unit
The AQUILA Partial Discharge Acquisition Unit complies with IEC 60270, IEC 61326-1, and IEC 61010-1 standards.

PD2U Partial Discharge Detector
The PD2U Partial Discharge Detector complies with IEC 60270, as stated on the product page.

PD3U Spectrum Analyzer Partial Discharge Detector and RIV Meter
The PD3U Spectrum Analyzer Partial Discharge Detector and RIV Meter complies with the following standards: - IEC 60270-2000 - IEEE C57.12.90 - NEMA 107-1987 - CISPR 18-2 - ANSI C63.3-1996 - VDE 876 - DIN EN 55016-1-1 These standards pertain to partial discharge measurements, radio influence voltage testing, and electromagnetic compatibility.

TD 1000 PLUS
The TD 1000 PLUS conforms to the following standards: - Electromagnetic Compatibility: - Directive no. 2004/108/EC - Applicable Standard: EN 61326-1 + A1 + A2 - Emission Standards: - EN 61000-3-2 - EN 61000-3-3 - CISPR16 (EN 55011 class A) - Immunity Standards: - EN 61000-4-2 - EN 61000-4-3 - EN 61000-4-4 - EN 61000-4-5 - EN 61000-4-6 - EN 61000-4-8 - EN 61000-4-11 - Low Voltage Directive: - Directive n. 2006/95/EC - Applicable Standard: EN 61010-1 - Protection: IP 2X - EN 60529 - Operating Temperature: 0 to 50°C; Storage: -20°C to 70°C - Relative Humidity: 5 - 95% without condensing - Vibration: IEC 68-2-6 (20 m/s² at 10 – 150 Hz) - Shock: IEC 68-2-27 (15 g; 11 ms; half-sine) - Altitude: less than 2000 m
T 3000
The T 3000 primary current injection test set conforms to the following standards: - Electromagnetic Compatibility: Directive no. 2004/108/EC. Applicable Standard: EN 61326-1 + A1 + A2 - Low Voltage Directive: Directive n. 2006/95/EC. Applicable standards for a class I instrument, pollution degree 2, Installation category II: - CEI EN 61010-1 - IEC 60529 These standards ensure the T 3000 meets the necessary requirements for electromagnetic compatibility and safety.
RELTEST 1000
The RELTEST 1000 product page mentions compliance with the following standards: - Electromagnetic compatibility: Directive 2004/108/EC, applicable standard EN61326-1 + A1 + A2. - Low voltage: Directive 2006/95/EC (CE conform), applicable standard CEI EN 61010-1. These standards pertain to electromagnetic compatibility and low voltage safety requirements, respectively.

T 2000
The T 2000 test set conforms to the following standards: - Electromagnetic Compatibility: Directive no. 2004/108/EC. Applicable Standard: EN 61326-1 + A1 + A2. - Low Voltage Directive: Directive n. 2006/95/EC. Applicable standard for a class I instrument, pollution degree 2, installation category II: EN 61010-1. In particular: - Inputs/outputs protection: IP 2X - IEC 60529; 4X for the HV output - Operating temperature: 0 to 50 °C; storage: -20 °C to 70 °C - Relative humidity: 5 - 95% without condensing
iCT1
The iCT1 product page mentions the following standards: - IEC EN 60044-1 - IEC EN 60044-2 - IEC EN 60044-5 - IEC EN 60044-6 - IEC EN 60044-7 - IEC EN 61869-x - ANSI/IEEE C57.13.1 These standards pertain to the testing of current and voltage transformers, as detailed in the product specifications.
View Product
Automated Dielectric Breakdown Test Set for Insulating Materials (D149)
Designed to measure dielectric breakdown and dielectric strength of a wide range of solid electrical insulating materials, at commercial power frequencies, within the ASTM D149 and IEC 60243-1 standards as well as other comparable international standards. Standard output voltages up to 100 kV AC and DC Selectable automatic or manual operating modes Test chamber with safety interlock, stress relief shielding, and transparent door Wide variety of test fixtures with electrodes Hot and cold oil baths